The Litre Counter is of the TIME-FLOW type and measures the passage of water in liters or gallons. *inlet - outlet: 3/8'' MNPT
The LCD display signals by flashing and with an acoustic alarm when the limit of the filter's inserted capacity is reached.
Equipped with instant detection of the flow rate of water passage.
Battery operated with 2 mini-type (2 AAA) alkaline batteries with a one-year life. When the batteries run out, the last processed data will be automatically stored inside the instrument.
INSTRUCTIONS FOR USE
Battery Installation
Slide the battery compartment cover and insert 2 AA batteries. Close the lid
Set the capacity for the filter
Press and hold DISPLAY for 4-5 seconds. then press RESET and release both buttons.
The DigiFlow 8000T will enter the filter capacity registration procedure.
Now press DISPLAY to choose the filter capacity. The sequence is 100-200-300….9800-19900-OFF.
By holding down DISPLAY you can accelerate the selection sequence.
After choosing the correct capacity, press RESET to save the setting.
Now press DISPLAY to select after how many days (day) the liter counter will have to emit the alarm.
The sequence is 30-60-90-120...-OFF.
The setting procedure will end, returning to the original state, if there is no input for 10 seconds.
Operations
The DigiFlow 8000T will automatically turn on when water passes through.
It will automatically turn off after 10 seconds if there is no water passage.
Press DISPLAY to view the volume of water passed or press DISPLAY again to view the remaining filter capacity.
End of capacity alarm
When the filter reaches 0 capacity the Digiflow will produce an audible alarm to alert the user to change the cartridges.
Press RESET to turn off the alarm and restore the filter capacity.
Low battery alarm
When the battery power is lower than the normal working level. a buzzer will emit two beeps to warn you to change the batteries. The information will be retained in memory if the battery is completely discharged or removed.
Reset
Press and hold RESET for 8 seconds to reset the liter counter.